If chopped firewood is used as
the fuel, no funnel is needed. If
wood chips are used as the
fuel, the funnel with correct
inclination is needed. If the
inclination is not correct the
wood chips easily form an arch
and stick (burn) on the inner
side of the funnel A correctly
designed funnel makes the fuel
flow smoothly into the
combustion chamber and
assists drying of the fuel. The
correct inclination for the
funnel is 60° and the diameter
of the lower part for 4 liter ICE
is 200 mm. The diameter of the
lower part of the funnel shall
always be 2/3 of the diameter
of the combustion chamber. The
distance between the lower end
of the funnel and the air nozzle
plane must be 200 mm.
If the wood chips stick (burn)
on the inner wall of the funnel,
the funnel must be lifted
upwards. A guide plate must
also be welded onto the funnel
to guide the condensing liquid
to the collection channel. On
the inner side of the outer
cylinder is also a collection
channel for the condensing
liquid with a connection to the
outside. The channel must be
inclined to make the liquid
flow to the collection tank. The
collection tank must be
gas-tight and spacious enough,
suitable volume is 10 liter. If the collection channel is not inclined it will soon be stuck
and the generator will not function properly because the moisture cannot escape from the
combustion chamber. Inside the lower end of the outer cylinder is a flange for connecting
the fuel reservoir to the other parts of the generator. To make the installation easy there
are openings on the outer mantle just where the connecting bolts are placed. The flange
and the collection channel are welded together on the inside. Due to this the openings on
the outer mantle do not affect the gas tightness.
The gasket of the fuel reservoir lid is made of silicone tubing or asbestos string treated
with graphite. The lid is connected to a leaf spring. The force of the spring causes the lid
to close tightly. The lid serves also as an emergency valve through which the excess
pressure in the generator can escape if the gas ignites in the combustion chamber or in
the fuel reservoir.
Translated by Olli.